Sander Ozonisatoren

Miniature Ozonisers

Application for small water quantities or little airflow rates. Available as Compact Design in a Case (see pict. 1) or as Built-in Printed Circuit (see pict. 2).

According to the requirements suitable for operation with

  • normal ambient air (rH approx. 50 %)
  • dry air (dew point DP -10 .... - 60°C) or
  • oxygen.

The units can be designed for

  • vacuum operation and for
  • overpressure operation (up to approx. 0,8 bar - custom designed units even higher).

Standard units from our series production are available. We also offer custom designed series.

Nominal Output
mg Ozone/h
Ambient Air
50% rH
Dry Air
-40°C DP
Oxygen
mg Ozone/h
25 12 25 50
50 25 50 100
100 50 100 200
200 100 200 400
300 150 300 600
500 250 500 1000